Milk Cooling Tank 500 Litres model CDX0.5KOTSC1P Direct Expansion Cooling Tank (Open Tank Semi Cylindrical Rectangular Shape) Capacity 500 Litres Has Large Opening Lids For Easy Access and Rounded Internal Corners to facilitate thorough Cleaning Tank Insulation Is Provided By Factory Injected Polyurethane Foam Of 50mm All Control System Integral Condensing Units Hermetic Type With R22 Refrigerant.
A | Bulk Milk Cooling Tank | 500 Ltr. | ||
1(a) | Rated Capacity in Litres. | 500 | ||
1 (b) | Gross Capacity in Litres. | 550 | ||
2 (a) | Make | KPL | ||
2 (b) | Model | CDX -500LOTSP | ||
3 | Material used for construction | AISI 304 | ||
4 | Shape and Orientation | Open Type Horizontal/Rectangular | ||
5 | Overall Dimensions and Weight | 2388X980X1100/200Kg (Approx) | ||
6 (a) | Thickness of inner shells | 2.0 MM | ||
6 (b) | Thickness of outer shells | 1.6 MM | ||
7 (a) | Number of Agitator | One | ||
7 (b) | RPM of agitator (s) (Approx.) | 23-25 RPM | ||
8 | CIP facility | Manual with Long Handle Brush | ||
9 (a) | Type of insulation | By injection in situ of High Density 40kg/cu.m, CFC free PUF without any imperfection and hygroscopicity, | ||
9 (b) | Thickness of insulation | 50 mm in walls & 90mm above evaporator | ||
9 © |
Efficiency of insulation | (0.019 Watt/MK) 50°C ambient the rate of rise of mean temp. of Milk Initially at 4°C shall not Exceed 1°C in 4 hour when rated volume is allowed to stand – still as per requirement of ISO 5708 2A(II) | ||
10 | Facility to Measure Milk Volume | SS Calibrated Dipstick with value chart | ||
11 | SS Milk Transfer Pump | 1HP-5000 LPH (10 MWC)(1 Phase) | ||
B | Refrigeration Unit | |||
1 | Type | Direct Expansion Open Type | ||
2 (a) | Type of Compressor | Hermetically Sealed Reciprocating | ||
2 (b) | Make of Compressor | EMERSON COPELAND/ DANFOSS/EQUIVALENT | ||
2 © | Model of Compressor | CR 22 / MT22 | ||
2 (d) | Size (Nominal HP) of compressor | 1 Ton | ||
3 | Condenser | Air Cooled, Finned Tube Type | ||
3 (a) | Make of Condenser | |||
3 (b) | Model of Condenser | CS22 | ||
3 (d) | Size of Condenser | 21″ X 24″- 3 Row | ||
4 (a) | No. of Compressor | One | ||
4 (b) | Min Cooling Capacity of Compressor (kcal/hr) at 0°C evaporating & 55°C Condensing Temperature | 3150 at 7.2°C | ||
5 | No. of Fans | One | ||
6 | Overall Dimensions and Weight of the Refrigeration Unit | 32″X24″X17.5″-60 KG | ||
7 | Receiver Size & Capacity | 6L | ||
8 (a) | Thermostatic Expansion Valve | DANFOSS TEX-2T WITH EQUALISER | ||
8 b) | Thermostatic Expansion Valve Make | DANFOSS / ALCO | ||
8 c) | Thermostatic Expansion Valve Size | DANFOSS TEX-2 WITH EQUALISER | ||
8 d) | Thermostatic Expansion Valve Capacity | ORIFACE-5 | ||
9 | Type of Refrigerant | Freon-R 22 / Eco friendly | ||
10 | Power Supply | Single Phase | ||
C | Design Parameters | |||
1 | Ambient temperature considered for design | 43 Deg C | ||
2 | Maximum Cooling Time considered for all and second milking | For All Milking 3.0 Hours & for Second Milking 1.5 Hours | ||
3 | Temperature range considered for ALL & SECOND Milking | All Milking – 35° C – 4° C Second Milking 10°C to 4°C | ||
D | Electricals | |||
Power Supply | Single Phase | |||
1 | Connected Load | Watts/Amps | ||
2 | Compressor | 1 Ton / 6.0 amps | ||
3 | Condenser Fan | 180/0.4 Amps | ||
4 | Agitator | 120 W/ 0.4 AMP | ||
6 | Maximum/Surge current drawn by the Compressor (S) | 1 KW / 6.0 Amp |